Purifying the entire air in spacious area by installing unit to air conditioner vent.
Generate positive and negative ions same as the ions exist in the natural world through plasma discharge and release into the air.
Change to OH radicals which are highly oxidizing when they adhere to the surfaces of airborne microbes, such as mold and viruses. They remove hydrogen from the surface proteins, breaking them down.
The OH radicals combine with hydrogen(H) to form water (H20) which is returned to the air.
In a test space of 31 m³
◎In a test Ion Concentration of 25, 000 ions/ cm³
Effect after 83 minutes in a test space of 31 m³.
◎In a test Ion Concentration of 3, 000 ions/ cm³
Effect after 195 minutes in a test space of 31 m³.
*1[airborne mold] • Test institution: Ishikawa Health Service Association • Test method: The Plasmacluster ions were released in test space of 31 m³. Airborne mold was measured with an air sampler. • Test results: (1) 99% of mold was eliminated after 83 minutes in a test of Ion Concentration of 25, 000 ions/ cm³. (2) 99 % of mold was eliminated after 195 minutes in a test of Ion Concentration of 3, 000 ions/ cm³
In a test space of 31/40 m³
◎In a test Ion Concentration of 25, 000 ions/ cm³
Effect after 14 minutes in an airtight test space of 31 m³.
◎In a test Ion Concentration of 4, 700 ions/ cm³
Effect after 38 minutes in an airtight test space of 31 m³.
*2[airborne bacteria] 1. In a test Ion Concentration of 25, 000 ions/ cm³: • Test institution: Ishikawa Health Service Association • Test method: One type of airborne bacteria and Plasmacluster ions were released in test space of 31 m³. After that, bacteria in the test space were collected and airborne bacteria elimination rate was measured. • Test results: 99% of bacteria was suppressed after 14 minutes. 2. In a test Ion Concentration of 4, 700 ions/ cm³: • Test institution: Dr. Melvin W. First, Professor Emeritus, Harvard School of Public Health • Test method: One type of airborne bacteria and Plasmacluster ions were released in test space of 40 m³. After that, bacteria in the test space were collected and airborne bacteria elimination rate was measured. • Test results: 99% of bacteria was suppressed after 38 minutes.
In a test space of 31 m³
◎In a test Ion Concentration of 3, 000 ions/ cm³※
Effect after 4 weeks (24 hours per day) in a living space of 31 m³
*3[airborne allergens] • Test institution: Hiroshima University (Graduate School of Advanced Sciences of Matter) • Test method: The act of Airborne allergens in the actual living space which was not cleaned were measured using the ELISA method. Its growth rate was calculated. (Ion Concentration of 3, 000 ions/ cm³) • Test results: The increase of airborne allergens of mite was confirmed to be suppressed after 4 weeks. (In a test with the Plasmacluster Ion Generating Unit)
※ With the Plasmacluster Ion Generating Unit)
In a test space of 25 m³
◎In a test Ion Concentration of 25, 000 ions/ cm³
Effect after 66 minutes in an airtight test space of 25 m³.
◎In a test Ion Concentration of 7, 000 ions/ cm³
Effect after 83 minutes in an airtight test space of 25 m³.
*4[airborne viruses] • Test institution: Pasteur Institute of Ho Chi Minh City, Vietnam • Test method: Airborne virus and the Plasmacluster ions were released in a test space. After that, viruses were collected in a test space and airborne virus elimination rate was measured. • Tested substance: One type of airborne virus • Test results: 99% of viruses were eliminated after 66 minutes.
In a test space of 41 m³
◎In a test Ion Concentration of 25, 000 ions/ cm³, odors were reduced to an unnoticeable level
Effect after 55 minutes in a test space of 41 m³. ※
◎In a test Ion Concentration of 7, 000 ions/ cm³, odors were reduced to an unnoticeable level
Effect after 80 minutes in a test space of 41 m³. ※
*5[airborne viruses] • Test institution: Japan Cash Machine Co., LTD. • Test method: Test method: Using a six-level odor intensity indication method, the effectiveness of deodorizing a test specimen impregnated with tobacco smoke odor when the Plasmacluster ions were irradiated was evaluated in a test space of 41 m³. • Test results: (1) Odors were reduced to an unnoticeable level after 55 minutes in a test Ion Concentration of 25,000 ions/ cm³. ※ (2) Odors were reduced to an unnoticeable level after 80 minutes in a test Ion Concentration of 7,000 ions/ cm³. ※
※ The odor elimination effect will vary depending on factors such as the type and strength of the odor, and the material that the odor adheres to.
In a test space of 41 m³
●Suppresses house dusts and pollens adhere to the clothing such as curtains and couches.
◎In a test Ion Concentration of 25, 000 ions/ cm³, initial potential was reduced from 5 kV to 0.5 kV
Effect after 2.5 minutes in a test space of 41 m³.
◎In a test Ion Concentration of 7, 000 ions/ cm³, initial potential was reduced from 5 kV to 0.5 kV
Effect after 10 minutes in a test space of 41 m³.
*6[static electricity] • Test institution: Japan Cash Machine Co., LTD. • Test method: A Plasmacluster ions were irradiated to a metal sensing plate charged to 5 kV in a test space of 41 m³ based on JIS TR C 0027-1. The time needed to reduce a 5 kV charged test specimen to 0.5 kV was measured. • Test results: (1) Static electricity was reduced from 5 kV to 0.5 kV in 2.5 minutes in a test Ion Concentration of 25,000 ions/ cm³. (2) Static electricity was reduced from 5 kV to 0.5 kV in 10 minutes in a test Ion Concentration of 7,000 ions/ cm³.
Name |
PCI-T2 |
Dimensions in mm |
92 (D) × 520 (W) × 66.4 (H) |
Power Consumption |
2.5W(with LED) / 1.7W(without LED) |
Rated Voltage |
DC12V |